SmartZone Affiliation Hold Off |
(Trunking Wide, Advanced) |
![]()
Selects the amount of time that the radio waits before connecting to a new Trunking site. This timer begins once the radio leaves the current Trunking site due to a control channel connection failure. This selected time is used by the radio as a randomized average. This selection applies only when in SmartZone operation for " Type II" Trunking Systems and therefore to all "Type II" Trunking Personalities. Time is in seconds.
![]()
When the radio is model / option capable.
![]()
1, 3, 7, 15, 31, 63, 127 and 255 seconds. |